{"created":"2023-07-25T08:12:25.341988+00:00","id":12766,"links":{},"metadata":{"_buckets":{"deposit":"b2fe7a27-d51d-4e60-9c5a-4e2a3d33efac"},"_deposit":{"created_by":18,"id":"12766","owners":[18],"pid":{"revision_id":0,"type":"depid","value":"12766"},"status":"published"},"_oai":{"id":"oai:ir.kagoshima-u.ac.jp:00012766","sets":["228:262:4828","39:40"]},"author_link":["105684","105685","105686","105687"],"item_7_biblio_info_5":{"attribute_name":"収録雑誌名","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1980-12-25","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"208","bibliographicPageStart":"203","bibliographicVolumeNumber":"29","bibliographic_titles":[{"bibliographic_title":"鹿児島大学水産学部紀要","bibliographic_titleLang":"ja"},{"bibliographic_title":"Memoirs of Faculty of Fisheries Kagoshima University","bibliographic_titleLang":"en"}]}]},"item_7_date_6":{"attribute_name":"作成日","attribute_value_mlt":[{"subitem_date_issued_datetime":"1980-12-25","subitem_date_issued_type":"Issued"}]},"item_7_description_4":{"attribute_name":"要約(Abstract)","attribute_value_mlt":[{"subitem_description":"The present experiments were conducted to measure the oxygen consumption of fish by a\nsingle electrode in a constant flow system.\nA cylindrical respiratory chamber with feces collector was employed in this experiment.\nThe oxygen electrode of DO meter (YSI model 57) with stirrer was suspended from an arm\nwhich was manipulated by the vertical movement of water within a pipet cleaner. The electrode was alternated between inlet water and outlet water of the respiratory chamber at ten minutes intervals by this apparatus.\nThe coefficient of relationship between fish metabolism measured by oxygen electrode and\nthe values obtained by the Winkler method was +0.98 for the resting metabolism of yellowtail\n(Av. 136±11 ml/kg/hr) at temperatures of 12.1 to 13.1°C.\nIt can be said from these results that the single oxygen electrode method: has superior efficiency (i.e. lower instrumental error) in comparison to double oxygen electrodes at inlet and outlet of the respiratory chamber; has similar accuracy to the Winkler method; and thus, merits the\nrecording of hourly dissolved oxygen variations.","subitem_description_language":"en","subitem_description_type":"Other"}]},"item_7_publisher_23":{"attribute_name":"公開者・出版者","attribute_value_mlt":[{"subitem_publisher":"鹿児島大学","subitem_publisher_language":"ja"},{"subitem_publisher":"Kagoshima University","subitem_publisher_language":"en"}]},"item_7_source_id_7":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0453087X","subitem_source_identifier_type":"PISSN"}]},"item_7_source_id_9":{"attribute_name":"NII書誌ID","attribute_value_mlt":[{"subitem_source_identifier":"AN00040498","subitem_source_identifier_type":"NCID"}]},"item_7_subject_15":{"attribute_name":"NDC","attribute_value_mlt":[{"subitem_subject":"663","subitem_subject_scheme":"NDC"}]},"item_7_version_type_14":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"門脇, 秀策","creatorNameLang":"ja"},{"creatorName":"KADOWAKI, Shusaku","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"105684","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"中薗, 貫幸","creatorNameLang":"ja"},{"creatorName":"NAKAZONO, Tsurayuki","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"105685","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"加世堂, 照男","creatorNameLang":"ja"},{"creatorName":"KASEDO, Teruo","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"105686","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"平田, 八郎","creatorNameLang":"ja"},{"creatorName":"HIRATA, Hachiro","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"105687","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2016-10-31"}],"displaytype":"detail","filename":"AN00040498_v29_p203-208.pdf","filesize":[{"value":"567.3 kB"}],"format":"application/pdf","mimetype":"application/pdf","url":{"label":"AN00040498_v29_p203-208.pdf","objectType":"fulltext","url":"https://ir.kagoshima-u.ac.jp/record/12766/files/AN00040498_v29_p203-208.pdf"},"version_id":"bb43b0a7-4f1e-459c-81bf-c92f6fd4ff46"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"同一電極法による魚介類の酸素消費量の連続測定装置","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"同一電極法による魚介類の酸素消費量の連続測定装置","subitem_title_language":"ja"},{"subitem_title":"An Apparatus for Continuous Records of Fish Metabolism by a Single Oxygen Electrode","subitem_title_language":"en"}]},"item_type_id":"7","owner":"18","path":["40","4828"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2012-05-07"},"publish_date":"2012-05-07","publish_status":"0","recid":"12766","relation_version_is_last":true,"title":["同一電極法による魚介類の酸素消費量の連続測定装置"],"weko_creator_id":"18","weko_shared_id":-1},"updated":"2024-07-30T01:17:28.250576+00:00"}