{"created":"2023-07-25T08:13:39.041413+00:00","id":14530,"links":{},"metadata":{"_buckets":{"deposit":"5f5a10db-c5dc-478f-bb1e-0acca8201eb7"},"_deposit":{"created_by":18,"id":"14530","owners":[18],"pid":{"revision_id":0,"type":"depid","value":"14530"},"status":"published"},"_oai":{"id":"oai:ir.kagoshima-u.ac.jp:00014530","sets":["57:86"]},"author_link":["132655"],"item_5_biblio_info_5":{"attribute_name":"収録雑誌名","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2019","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"53","bibliographicPageStart":"47","bibliographicVolumeNumber":"89","bibliographic_titles":[{"bibliographic_title":"Angle Orthodontist","bibliographic_titleLang":"en"}]}]},"item_5_date_granted_54":{"attribute_name":"学位授与年月日 ","attribute_value_mlt":[{"subitem_dategranted":"2019-01-20"}]},"item_5_degree_grantor_53":{"attribute_name":"学位授与機関","attribute_value_mlt":[{"subitem_degreegrantor":[{"subitem_degreegrantor_language":"ja","subitem_degreegrantor_name":"鹿児島大学"}],"subitem_degreegrantor_identifier":[{"subitem_degreegrantor_identifier_name":"17701","subitem_degreegrantor_identifier_scheme":"kakenhi"}]}]},"item_5_degree_name_42":{"attribute_name":"学位名","attribute_value_mlt":[{"subitem_degreename":"博士(歯学)","subitem_degreename_language":"ja"},{"subitem_degreename":"Doctor of Philosophy in Dental Science","subitem_degreename_language":"en"}]},"item_5_description_17":{"attribute_name":"ファイル(説明)","attribute_value_mlt":[{"subitem_description":"博士論文全文, 最終試験結果の要旨, 論文審査の要旨, 博士論文要旨","subitem_description_language":"ja","subitem_description_type":"Other"}]},"item_5_description_4":{"attribute_name":"要約(Abstract)","attribute_value_mlt":[{"subitem_description":"Objective: To clarify the in vivo effect of an automatic embedding device on miniscrew stability.\nMaterials and Methods: 42 miniscrews were implanted into rabbit femurs. The miniscrews with the novel auxiliary device formed the auxiliary group (n = 11 at 4 weeks; n = 11 at 8 weeks) and the miniscrews without the auxiliary device formed the nonauxiliary control group (n = 9 at 4 weeks; n = 11 at 8 weeks). Cortical bone thickness, distance from the cortical bone surface to the miniscrew head, and implantation depth of the spike were measured using micro-computed tomography. The mechanical retention force was evaluated by measuring the displacement of the miniscrew head after it was loaded perpendicular to its long axis. In the lateral displacement test, effects of the auxiliary (with vs without auxiliary), and time (4 vs 8 weeks) were assessed using the Brunner–Langer nonparametric analysis of longitudinal data in factorial experiments.\nResults: The mean implantation depth of the spike in the auxiliary group at 4 and 8 weeks was 0.28mm (median: 0.33; SD: 0.12) and 0.37 mm (median: 0.33; SD: 0.19), respectively. The retention force was approximately 2.0 to 2.8 and 1.6 to 1.8 times greater in the auxiliary group than in the nonauxiliary group at 4 and 8 weeks, respectively.\nConclusions: The auxiliary device improved the mechanical retention force without the need to increase miniscrew length or diameter. This may enable the safe use of miniscrews in difficult areas. (Angle Orthod. 2019;89:47–53.)","subitem_description_language":"en","subitem_description_type":"Other"}]},"item_5_dissertation_number_55":{"attribute_name":"学位授与番号","attribute_value_mlt":[{"subitem_dissertationnumber":"甲総研第489号"}]},"item_5_publisher_23":{"attribute_name":"公開者・出版者","attribute_value_mlt":[{"subitem_publisher":"The E. H. Angle Education and Research Foundation ","subitem_publisher_language":"en"},{"subitem_publisher":"鹿児島大学","subitem_publisher_language":"ja"},{"subitem_publisher":"カゴシマ ダイガク","subitem_publisher_language":"ja-Kana"}]},"item_5_relation_11":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"10.2319/121117-857.1","subitem_relation_type_select":"DOI"}}]},"item_5_relation_13":{"attribute_name":"情報源","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"Angle Orthodontist"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://www.angle.org/loi/angl","subitem_relation_type_select":"URI"}}]},"item_5_rights_12":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"© 2019 by The EH Angle Education and Research Foundation, Inc.","subitem_rights_language":"en"}]},"item_5_subject_15":{"attribute_name":"NDC","attribute_value_mlt":[{"subitem_subject":"497","subitem_subject_scheme":"NDC"}]},"item_5_text_44":{"attribute_name":"備考","attribute_value_mlt":[{"subitem_text_value":"【指導教員:宮脇正一】"}]},"item_5_text_47":{"attribute_name":"date.appl","attribute_value_mlt":[{"subitem_text_value":"【学位申請日】2018/9/30"}]},"item_5_version_type_14":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_abf2"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"大賀, 泰彦","creatorNameLang":"ja"},{"creatorName":"オオガ, ヤスヒコ","creatorNameLang":"ja-Kana"},{"creatorName":"Oga, Yasuhiko","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"132655","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2019-02-19"}],"displaytype":"detail","filename":"Diss_大賀_泰彦_ISK489_2018.pdf","filesize":[{"value":"1.1 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"Diss_大賀_泰彦_ISK489_2018","objectType":"fulltext","url":"https://ir.kagoshima-u.ac.jp/record/14530/files/Diss_大賀_泰彦_ISK489_2018.pdf"},"version_id":"7a4be6c4-e911-41f9-a0c6-895d76e3bac3"},{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2019-01-28"}],"displaytype":"detail","filename":"Result_Oga_Yasuhiko_isk_489_2019.pdf","filesize":[{"value":"1.3 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"Result_Oga_Yasuhiko_isk_489_2019","objectType":"other","url":"https://ir.kagoshima-u.ac.jp/record/14530/files/Result_Oga_Yasuhiko_isk_489_2019.pdf"},"version_id":"1cec4fd3-d53b-4283-9dbb-ea88fee9ae3e"},{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2019-01-28"}],"displaytype":"detail","filename":"Comments_Oga_Yasuhiko_isk_489_2019.pdf","filesize":[{"value":"468.3 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"Comments_Oga_Yasuhiko_isk_489_2019","objectType":"other","url":"https://ir.kagoshima-u.ac.jp/record/14530/files/Comments_Oga_Yasuhiko_isk_489_2019.pdf"},"version_id":"2e910946-b090-4e19-a1d7-f790400fbe17"},{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2019-02-18"}],"displaytype":"detail","filename":"Abstract_大賀_泰彦_4513800030_2018.pdf","filesize":[{"value":"52.0 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"Abstract_大賀_泰彦_4513800030_2018","objectType":"abstract","url":"https://ir.kagoshima-u.ac.jp/record/14530/files/Abstract_大賀_泰彦_4513800030_2018.pdf"},"version_id":"af4e66bd-cec7-4386-a2d6-ff1db0eda135"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Skeletal anchorage","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Animal model","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Miniscrew","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"doctoral thesis","resourceuri":"http://purl.org/coar/resource_type/c_db06"}]},"item_title":"Evaluation of miniscrew stability using an automatic embedding auxiliary skeletal anchorage device","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Evaluation of miniscrew stability using an automatic embedding auxiliary skeletal anchorage device","subitem_title_language":"en"},{"subitem_title":"自動埋入型骨固定補助装置を併用した歯科矯正用アンカースクリューの維持力の検討","subitem_title_language":"ja"}]},"item_type_id":"5","owner":"18","path":["86"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2019-01-28"},"publish_date":"2019-01-28","publish_status":"0","recid":"14530","relation_version_is_last":true,"title":["Evaluation of miniscrew stability using an automatic embedding auxiliary skeletal anchorage device"],"weko_creator_id":"18","weko_shared_id":-1},"updated":"2024-01-09T01:48:58.289910+00:00"}