{"created":"2023-07-25T08:03:38.447250+00:00","id":1642,"links":{},"metadata":{"_buckets":{"deposit":"9c53989e-9aa4-4125-908f-7d4625a14d1e"},"_deposit":{"created_by":18,"id":"1642","owners":[18],"pid":{"revision_id":0,"type":"depid","value":"1642"},"status":"published"},"_oai":{"id":"oai:ir.kagoshima-u.ac.jp:00001642","sets":["35:67"]},"author_link":["86141","86142","86143","86144","86145","86146"],"item_6_biblio_info_5":{"attribute_name":"収録雑誌名","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2008-04-01","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"4","bibliographicPageEnd":"725","bibliographicPageStart":"720","bibliographicVolumeNumber":"33","bibliographic_titles":[{"bibliographic_title":"Renewable Energy","bibliographic_titleLang":"en"}]}]},"item_6_date_6":{"attribute_name":"作成日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2008-04-01","subitem_date_issued_type":"Issued"}]},"item_6_description_4":{"attribute_name":"要約(Abstract)","attribute_value_mlt":[{"subitem_description":"A room-cooling system of 2 kW capacity fueled by wood pellets was designed, built and tested. The system was demonstrated during \nsummer at the Yakushima Field Station of Kagoshima University, Japan. It contained a pellet feeder, a pellet burner, a heat exchanger, a \nlithium bromide.water absorption heat pump and a control unit. The volume of the test room was 36.9 m3 and ambient temperature 30 °C. \nThe airflow temperature from the room unit was decreased to 16 °C by the system, and the room temperature could be successfully \ncontrolled to 24 °C steady state. Room heating in winter was also demonstrated. Since the air was heat exchanged, the overall energy \nefficiency of the cooling system was low at about 19%. However, the calculation based on the heat flow showed that the efficiency could \nbe enhanced to about 75% by direct heating of the regenerator by the flue gas.","subitem_description_language":"en","subitem_description_type":"Other"}]},"item_6_publisher_23":{"attribute_name":"公開者・出版者","attribute_value_mlt":[{"subitem_publisher":"Elsevier","subitem_publisher_language":"en"}]},"item_6_source_id_7":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"09601481","subitem_source_identifier_type":"PISSN"}]},"item_6_source_id_9":{"attribute_name":"NII書誌ID","attribute_value_mlt":[{"subitem_source_identifier":"AA10802274","subitem_source_identifier_type":"NCID"}]},"item_6_subject_15":{"attribute_name":"NDC","attribute_value_mlt":[{"subitem_subject":"570","subitem_subject_scheme":"NDC"}]},"item_6_version_type_14":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_ab4af688f83e57aa","subitem_version_type":"AM"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Kai, Takami","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Uemura, Yoshimitsu","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Teraoka, Yukio","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Takahashi, Takeshige","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Hatate, Yasuo","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Yoshida, Masahiro","creatorNameLang":"en"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2016-10-27"}],"displaytype":"detail","filename":"RENE2007.pdf","filesize":[{"value":"177.7 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"RENE2007.pdf","objectType":"fulltext","url":"https://ir.kagoshima-u.ac.jp/record/1642/files/RENE2007.pdf"},"version_id":"be720361-823c-4f70-8f39-7851e0564925"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Wood pellets","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Space cooling","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Wood chips","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Absorption heat pump","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Design and operation of an air-conditioning system fueled by wood pellets","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Design and operation of an air-conditioning system fueled by wood pellets","subitem_title_language":"en"}]},"item_type_id":"6","owner":"18","path":["67"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2010-10-05"},"publish_date":"2010-10-05","publish_status":"0","recid":"1642","relation_version_is_last":true,"title":["Design and operation of an air-conditioning system fueled by wood pellets"],"weko_creator_id":"18","weko_shared_id":-1},"updated":"2024-02-07T05:04:04.706962+00:00"}