@article{oai:ir.kagoshima-u.ac.jp:00002155, author = {川原, 浩一郎 and KAWAHARA, Koichiro}, journal = {鹿児島大学工学部研究報告, The research reports of the Faculty of Engineering, Kagoshima University}, month = {Sep}, note = {Grounded-base type is stable in a common use of an ampifier. In case of a heavy inductive load it is supposed to be instable by negative input impedance which arises from internal current feed-back. The author reported previously the usefulness of h-parameter analysis of the stability of grounded-collector, g-parameter is introduced into the approach of the critical behaviour of grounded-base in the aspect of duality. A rational manipulation of an amplification property and circuitry reveals the feed-back characteristics of grounded-base and -collector. Additionally a loop gain which is well introduced into this analysis contributes to the stability criterion.}, pages = {29--31}, title = {ベース接地形トランジスタ増幅器の帰還特性のgパラメータによる解析 : 誘導性負荷時のナイキスト線図による安定判別}, volume = {10}, year = {1968} }