{"created":"2023-07-25T08:06:18.495467+00:00","id":5030,"links":{},"metadata":{"_buckets":{"deposit":"4091aa41-d7d8-44f7-858a-f355f4e3e00e"},"_deposit":{"created_by":3,"id":"5030","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"5030"},"status":"published"},"_oai":{"id":"oai:ir.kagoshima-u.ac.jp:00005030","sets":["228:262:4844"]},"author_link":["102788","102783","102785","102784","102786","102787"],"item_7_alternative_title_18":{"attribute_name":"別言語のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"Paddle Wheel of Movable Float Type for a Large Circulating Tank as Compared to that of Fixed Float Type."}]},"item_7_alternative_title_19":{"attribute_name":"タイトルよみ","attribute_value_mlt":[{"subitem_alternative_title":"オオガタ カイリュウ スイソウヨウ カドウヨク スイシャ ト コテイヨク スイシャ ノ ヒカク ニツイテ"}]},"item_7_biblio_info_5":{"attribute_name":"収録雑誌名","attribute_value_mlt":[{"bibliographicPageEnd":"109","bibliographicPageStart":"104","bibliographicVolumeNumber":"13","bibliographic_titles":[{"bibliographic_title":"鹿児島大学水産学部紀要=Memoirs of Faculty of Fisheries Kagoshima University"}]}]},"item_7_date_6":{"attribute_name":"作成日","attribute_value_mlt":[{"subitem_date_issued_datetime":"1964-12-10"}]},"item_7_description_4":{"attribute_name":"要約(Abstract)","attribute_value_mlt":[{"subitem_description":"On the repair works of the large circulating tank, the paddle wheel of the fixed float type\nwas changed for that of movable float type and the thin steel plates such as the fixed and the movable current plates which were corroded with rust in the lapse of eight years were replaced\nby hard vinyl plastic plates.\nThen, the following two profits were obtained:\n1). The pulsatory motion of water flow, one of defects of the fixed float type paddle wheel,\nwas not observed with the new movable float type and the velocity of water flow gave a\nvalue 10~30% larger than that obtainable before.\n2). By using anti-corrosion materials as hard vinyl plastic, brass and cast iron for all apparatus exposed to the tank water,\nthe occurrence of rust was stopped and the tank water\nkeeps clear for many days.","subitem_description_type":"Other"}]},"item_7_full_name_2":{"attribute_name":"著者よみ","attribute_value_mlt":[{"nameIdentifiers":[{}],"names":[{"name":"ナラサコ, ヨシカズ"}]},{"nameIdentifiers":[{}],"names":[{"name":"ナカヤマ, ヒロシ"}]}]},"item_7_full_name_3":{"attribute_name":"別言語の著者","attribute_value_mlt":[{"nameIdentifiers":[{}],"names":[{"name":"NARASAKO, Yoshikazu"}]},{"nameIdentifiers":[{}],"names":[{"name":"NAKAYAMA, Hiroshi"}]}]},"item_7_publisher_23":{"attribute_name":"公開者・出版者","attribute_value_mlt":[{"subitem_publisher":"鹿児島大学"}]},"item_7_source_id_7":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0453087X","subitem_source_identifier_type":"ISSN"}]},"item_7_source_id_9":{"attribute_name":"NII書誌ID","attribute_value_mlt":[{"subitem_source_identifier":"AN00040498","subitem_source_identifier_type":"NCID"}]},"item_7_subject_15":{"attribute_name":"NDC","attribute_value_mlt":[{"subitem_subject":"660","subitem_subject_scheme":"NDC"}]},"item_7_text_24":{"attribute_name":"公開者よみ","attribute_value_mlt":[{"subitem_text_value":"カゴシマ ダイガク"}]},"item_7_text_25":{"attribute_name":"公開者別名","attribute_value_mlt":[{"subitem_text_value":"Kagoshima University"}]},"item_7_version_type_14":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"奈良迫, 嘉一"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"中山, 博"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2016-10-28"}],"displaytype":"detail","filename":"AN00040498_v13_p104-109.pdf","filesize":[{"value":"1.9 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"AN00040498_v13_p104-109.pdf","url":"https://ir.kagoshima-u.ac.jp/record/5030/files/AN00040498_v13_p104-109.pdf"},"version_id":"cc49fcd2-654b-4b87-bfdb-e705b7a65831"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"大型回流水槽用可動翼水車と固定翼水車の比較について","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"大型回流水槽用可動翼水車と固定翼水車の比較について"}]},"item_type_id":"7","owner":"3","path":["40","4844"],"pubdate":{"attribute_name":"公開日","attribute_value":"2015-06-24"},"publish_date":"2015-06-24","publish_status":"0","recid":"5030","relation_version_is_last":true,"title":["大型回流水槽用可動翼水車と固定翼水車の比較について"],"weko_creator_id":"3","weko_shared_id":3},"updated":"2024-01-30T05:47:08.960175+00:00"}