{"created":"2023-07-25T08:09:08.837320+00:00","id":8657,"links":{},"metadata":{"_buckets":{"deposit":"c1a9b12c-4557-450c-9625-a3d2a1533368"},"_deposit":{"created_by":3,"id":"8657","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"8657"},"status":"published"},"_oai":{"id":"oai:ir.kagoshima-u.ac.jp:00008657","sets":[]},"author_link":["27991","118010","118009"],"item_8_alternative_title_18":{"attribute_name":"別言語のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"Influence of light irradiation on Vickers hardness of dual-cure cement polymerized under restorations"}]},"item_8_alternative_title_19":{"attribute_name":"タイトルよみ","attribute_value_mlt":[{"subitem_alternative_title":"キンゾク シュウフクブツ チョッカ ノ デュアルキュア レジンセメント ノ キカイテキ セイシツ ニオヨボス ヒカリショウシャ ノ エイキョウ"}]},"item_8_date_6":{"attribute_name":"作成日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2013-05-29"}]},"item_8_description_4":{"attribute_name":"要約(Abstract)","attribute_value_mlt":[{"subitem_description":"2011-2012年度科学研究費助成事業(科学研究費補助金(若手研究(B))研究成果報告書 課題番号:23792239 研究代表者:塩向大作(鹿児島大学・大学院医歯学総合研究科・助教)","subitem_description_type":"Other"},{"subitem_description":"本研究は、照射光がダイレクトに到達できない部分のデュアルキュアセメントの硬化に関して検討したものであり、その結果、硬化促進剤を含有するセルフエッチングプライマー塗布の必要性、また余剰レジンの除去後に辺縁部には再度の光照射を行い、セメントの重合促進を図らなくてはならないこと、修復物を装着した当日には、外力が加わる作業は最小限に留めるべきであることを示した。","subitem_description_type":"Other"},{"subitem_description":"This study evaluated the influence of the light transmittance of restoratives materials, the distance from the light irradiation area, and the lapsed time after light irradiation on the degree of polymerization of dual-cure cement (Panavia F2.0) which is placed to the area covered with restoratives by measuring Vickers micro hardness (Hv).\nWithin the limitations of this study, the following conclusions were drawn:\n1. Application of the self-etching primer also improved the polymerization of dual-cure\ncement in areas covered by the restoration.\n2. When installing a restoration to the abutment tooth using dual-cure resin cement in a clinical practice, an additional light irradiation to the marginal area is preferable to accelerate the polymerization of the cement.\n3. It is highly recommended to keep to a minimum stresses on the bonding interface the\nday that a prosthetic restoration is installed.","subitem_description_type":"Other"}]},"item_8_full_name_2":{"attribute_name":"著者よみ","attribute_value_mlt":[{"nameIdentifiers":[{}],"names":[{"name":"シオムキ, ダイサク"}]}]},"item_8_full_name_3":{"attribute_name":"別言語の著者","attribute_value_mlt":[{"nameIdentifiers":[{}],"names":[{"name":"SHIOMUKI, Daisaku"}]}]},"item_8_publisher_23":{"attribute_name":"公開者・出版者","attribute_value_mlt":[{"subitem_publisher":"鹿児島大学"}]},"item_8_subject_15":{"attribute_name":"NDC","attribute_value_mlt":[{"subitem_subject":"497.5","subitem_subject_scheme":"NDC"}]},"item_8_text_24":{"attribute_name":"公開者よみ","attribute_value_mlt":[{"subitem_text_value":"カゴシマ ダイガク"}]},"item_8_text_25":{"attribute_name":"公開者別名","attribute_value_mlt":[{"subitem_text_value":"Kagoshima University"}]},"item_8_text_41":{"attribute_name":"科研費番号 ","attribute_value_mlt":[{"subitem_text_value":"23792239"}]},"item_8_version_type_14":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"塩向, 大作"}],"nameIdentifiers":[{},{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2016-10-28"}],"displaytype":"detail","filename":"23792239.pdf","filesize":[{"value":"231.4 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"23792239.pdf","url":"https://ir.kagoshima-u.ac.jp/record/8657/files/23792239.pdf"},"version_id":"f5a78d64-196e-4f52-9e28-a4b1e8417432"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Dual-cure","subitem_subject_scheme":"Other"},{"subitem_subject":"Resin","subitem_subject_scheme":"Other"},{"subitem_subject":"Adhesive","subitem_subject_scheme":"Other"},{"subitem_subject":"Polymerization","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"research report","resourceuri":"http://purl.org/coar/resource_type/c_18ws"}]},"item_title":"金属修復物直下のデュアルキュアレジンセメントの機械的性質に及ぼす光照射の影響","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"金属修復物直下のデュアルキュアレジンセメントの機械的性質に及ぼす光照射の影響"}]},"item_type_id":"8","owner":"3","path":["80"],"pubdate":{"attribute_name":"公開日","attribute_value":"2013-10-01"},"publish_date":"2013-10-01","publish_status":"0","recid":"8657","relation_version_is_last":true,"title":["金属修復物直下のデュアルキュアレジンセメントの機械的性質に及ぼす光照射の影響"],"weko_creator_id":"3","weko_shared_id":3},"updated":"2023-12-25T07:18:50.299549+00:00"}