WEKO3
アイテム
共焦点レーザー走査型検眼鏡とOCTAにおける糖尿病網膜症患者の毛細血管瘤の検出率の比較
http://hdl.handle.net/10232/00032083
http://hdl.handle.net/10232/000320832a5dde5a-8c47-4eac-8740-d36b9a3537e1
名前 / ファイル | ライセンス | アクション |
---|---|---|
Diss_迫野_能士_ISK667_2022 (1.8 MB)
|
||
Abstract_迫野_能士_4519810187_2022 (172.3 kB)
|
|
|
Result_sakono_takato_isk_667 (148.3 kB)
|
|
|
Comments_sakono_takato_isk_667 (55.8 kB)
|
|
Item type | 学位論文 / Thesis or Dissertation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2022-08-29 | |||||
タイトル | ||||||
タイトル | Comparison of multicolor scanning laser ophthalmoscopy and optical coherence tomography angiography for detection of microaneurysms in diabetic retinopathy | |||||
タイトル言語 | en | |||||
タイトル | ||||||
タイトル | 共焦点レーザー走査型検眼鏡とOCTAにおける糖尿病網膜症患者の毛細血管瘤の検出率の比較 | |||||
タイトル言語 | ja | |||||
著者 |
迫野, 能士
× 迫野, 能士 |
|||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_db06 | |||||
資源タイプ | doctoral thesis | |||||
アクセス権 | ||||||
アクセス権 | open access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_abf2 | |||||
要約 | ||||||
内容記述タイプ | Other | |||||
内容記述 | This study aimed to evaluate the usefulness of multicolor (MC) scanning laser ophthalmoscopy (MC-SLO) in detecting microaneurysm (MA) in eyes with diabetic retinopathy (DR). This was a retrospective cross-sectional study. Eyes with DR underwent fluorescein angiography (FA), MC-SLO, optical coherence tomography angiography (OCTA), and color fundus photography (CFP) were analyzed. The foveal region was cut in an 6 × 6 mm image and the number of MA in each image was counted by retina specialists to determine the sensitivity and positive predictive value. FA results were used as the ground standard. MAs were classified as those with early, late, or no dye leakage based on FA images. Fifty-four eyes of 35 patients with an average age of 64.5 ± 1.24 years were included. The sensitivity of MA detection was 37.3%, 15.3%, and 4.12% in MC-SLO, OCTA, and CFP, respectively (P < 0.01 in each pair).The positive predictive value was 66.4%, 46.4%, and 27.6% in MC, OCTA, and CFP, respectively (P < 0.01 in each pair). Sensitivity for MAs with early leakage was 36.4% in MC-SLO, which was significantly higher than 4.02% in OCTA. MC-SLO was more useful in detecting MA in eyes with DR than OCTA. Takato Sakono, Hiroto Terasaki, Shozo Sonoda, Ryoh Funatsu, Hideki Shiihara, Eisuke Uchino, Toshifumi Yamashita & Taiji Sakamoto Comparison of multicolor scanning laser ophthalmoscopy and optical coherence tomography angiography for detection of microaneurysms in diabetic retinopathy Scientific Reports (2021) 11:17017 The version of record of this article, first published in Scientific Reports, is available online at Publisher’s website: https://doi.org/10.1038/s41598-021-96371-y |
|||||
内容記述言語 | en | |||||
作成日 | ||||||
日付 | 2022-08-05 | |||||
日付タイプ | Collected | |||||
出版タイプ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
NDC | ||||||
主題Scheme | NDC | |||||
主題 | 490 | |||||
ファイル(説明) | ||||||
内容記述 | 博士論文全文, 博士論文要旨, 最終試験結果の要旨, 論文審査の要旨 | |||||
公開者・出版者 | ||||||
出版者 | Springer Nature | |||||
出版者言語 | en | |||||
公開者・出版者 | ||||||
出版者 | 鹿児島大学 | |||||
出版者言語 | ja | |||||
公開者・出版者 | ||||||
出版者 | カゴシマ ダイガク | |||||
出版者言語 | ja-Kana | |||||
備考 | ||||||
備考 | 【指導教員:坂本泰二】 | |||||
date.appl | ||||||
appl | 【学位申請日】2022-05-11 | |||||
学位名 | ||||||
学位名の言語 | ja | |||||
学位名 | 博士(医学) | |||||
学位名 | ||||||
学位名の言語 | en | |||||
学位名 | Doctor of Philosophy in Medical Science | |||||
学位授与機関名 | ||||||
学位授与機関識別子Scheme | kakenhi | |||||
学位授与機関識別子 | 17701 | |||||
学位授与機関名の言語 | ja | |||||
学位授与機関名 | 鹿児島大学 | |||||
学位授与年月日 | ||||||
学位授与年月日 | 2022-08-23 | |||||
学位授与番号 | ||||||
学位授与番号 | 甲総研第667号 |