ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 医歯学総合研究科
  2. 医歯学総合研究科・学術誌論文

Conventional Multi-Planar Reconstruction Imaging Is Insufficient to Determine the Indication for Segmentectomy

http://hdl.handle.net/10232/00032552
http://hdl.handle.net/10232/00032552
00cede45-d77e-4c05-a4a6-68921a871048
名前 / ファイル ライセンス アクション
AA11035352_v26(5)_p256-262.pdf AA11035352_v26(5)_p256-262 (1.7 MB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2023-06-01
タイトル
タイトル Conventional Multi-Planar Reconstruction Imaging Is Insufficient to Determine the Indication for Segmentectomy
タイトル言語 en
著者 Nagata, Toshiyuki

× Nagata, Toshiyuki

WEKO 142872

en Nagata, Toshiyuki

Search repository
Ueda, Kazuhiro

× Ueda, Kazuhiro

WEKO 142873

en Ueda, Kazuhiro

Search repository
Suzuki, Souichi

× Suzuki, Souichi

WEKO 142874

en Suzuki, Souichi

Search repository
Tokuda, Yasuhiro

× Tokuda, Yasuhiro

WEKO 142875

en Tokuda, Yasuhiro

Search repository
Yunoki, Kentaro

× Yunoki, Kentaro

WEKO 142876

en Yunoki, Kentaro

Search repository
Imamura, Satomi

× Imamura, Satomi

WEKO 142877

en Imamura, Satomi

Search repository
Sato, Masami

× Sato, Masami

WEKO 142878

en Sato, Masami

Search repository
言語
言語 eng
キーワード
主題言語 en
主題Scheme Other
主題 lung cancer
キーワード
主題言語 en
主題Scheme Other
主題 segmentectomy
キーワード
主題言語 en
主題Scheme Other
主題 surgical margin
キーワード
主題言語 en
主題Scheme Other
主題 computer simulation
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
要約
内容記述タイプ Other
内容記述 Purpose: The diagnostic potential of conventional multi-planar reconstruction (MPR) images, which consist of horizontal, frontal, and sagittal section, in approximating the anatomical distance between tumors and intersegmental planes remains unclear. The aim of the present study was to clarify the validity of decision-making for segmentectomy based on MPR imaging and identify a specific tumor location that is likely to result in the overestimation of the anatomical margin on MPR images.
Methods: The study population included 33 patients who were considered eligible for segmentectomy based on the observation of MPR images, and verified using a commercially available image-analysis software whether the decision-making based on MPR images was indeed correct or not.
Results: MPR image-based assessment resulted in the overestimation of the anatomical margin in as many as 8 (24%) of the 33 patients. Overestimation predominantly occurred in cases involving patients with tumors at certain segments (right S1, right S2, right S3, left S3, and left S4) that had a complex and oblique intersegmental plane.
Conclusion: Conventional MPR image-based assessment frequently resulted in the overestimation of the anatomical margin. We recommend using software-based assessment preoperatively in patients with tumors in the risky segments, particularly in cases involving indistinct tumors.

Toshiyuki Nagata, Kazuhiro Ueda, Souichi Suzuki, Yasuhiro Tokuda, Kentaro Yunoki, Satomi Imamura, Masami Sato
Conventional Multi-Planar Reconstruction Imaging Is Insufficient to Determine the Indication for Segmentectomy
Annals of Thoracic and Cardiovascular Surgery 2020; 26: 256–262
https://doi.org/10.5761/atcs.oa.19-00291
内容記述言語 en
収録雑誌名 en : Annals of Thoracic and Cardiovascular Surgery

巻 26, 号 5, p. 256-262, 発行日 2020-02-19
作成日
日付 2020-02-19
日付タイプ Issued
ISSN
収録物識別子タイプ PISSN
ISSN 13411098
NII書誌ID(雑誌)
収録物識別子タイプ NCID
NC ID AA11035352
出版タイプ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
NDC
主題Scheme NDC
主題 490
公開者・出版者
出版者 The Editorial Committee of Annals of Thoracic and Cardiovascular Surgery
出版者言語 en
戻る
0
views
See details
Views

Versions

Ver.1 2023-07-25 09:35:45.777198
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3