WEKO3
アイテム
吹出し管を備えた吸込みノズルの空気輸送特性におよぼす吸込みノズル深さおよび吹出し管挿入長さの影響
http://hdl.handle.net/10232/0002000334
http://hdl.handle.net/10232/0002000334832011a4-3358-4b2f-8a30-722ee6583fb4
名前 / ファイル | ライセンス | アクション |
---|---|---|
https://doi.org/10.4164/sptj.58.294
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2024-05-22 | |||||
タイトル | ||||||
タイトル | 吹出し管を備えた吸込みノズルの空気輸送特性におよぼす吸込みノズル深さおよび吹出し管挿入長さの影響 | |||||
言語 | ja | |||||
タイトル | ||||||
タイトル | Effects of Insertion Length of Suction Nozzle and Injection Pipe on Pneumatic Conveying Characteristics of Suction Nozzle with Injection Pipe | |||||
言語 | en | |||||
著者 |
石原田, 秀一
× 石原田, 秀一× 福原, 稔× 高松, 皆光× 村上, 悠× 石外, 哲也× 中村, 悠× 中尾, 光博 |
|||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Pneumatic conveying | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Suction nozzle | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Loading ratio | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Efficiency | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Fluidization | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | open access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_abf2 | |||||
要約(Abstract) | ||||||
内容記述タイプ | Other | |||||
内容記述 | In the vacuum system of pneumatic conveying, the authors have proposed that a suction nozzle equipped with an injection pipe at the center would provide a highly dense, highly efficient method of transporting powder and particles. In this paper, we examined the effects of the insertion length of the suction nozzle and the injection pipe, by attaching the injection port on the outer part of the suction nozzle. The loading ratio for both cases (the injection ports positioned at the center and outer part) was not affected by the insertion length of the suction nozzle. However, the loading ratio incretion rate by the insertion length of the injection pipe was larger when the injection port was attached on the suction nozzle’s outer part. From the perspective of the nozzle efficiency analysis, it was concluded that the outer injection port can be used adequately during the high flow rate ratio range. | |||||
言語 | en | |||||
収録雑誌名 |
ja : 粉体工学会誌 en : Journal of the Society of Powder Technology, Japan 巻 58, 号 6, p. 294-301, 発行日 2021-06-10 |
|||||
作成日 | ||||||
日付 | 2021-06-10 | |||||
日付タイプ | Issued | |||||
ISSN | ||||||
収録物識別子タイプ | EISSN | |||||
収録物識別子 | 18837239 | |||||
NII書誌ID(雑誌) | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN00222757 | |||||
DOI | ||||||
関連タイプ | isIdenticalTo | |||||
識別子タイプ | DOI | |||||
関連識別子 | https://doi.org/10.4164/sptj.58.294 | |||||
出版タイプ | ||||||
出版タイプ | NA | |||||
出版タイプResource | http://purl.org/coar/version/c_be7fb7dd8ff6fe43 | |||||
公開者・出版者 | ||||||
出版者 | 粉体工学会 | |||||
言語 | ja |